Dental Tribune International

Atraumatic extraction of maxillary second premolar

By Dr Manouchehr Kiaei, Sweden
November 29, 2019

A 76-year-old female patient visited our clinic owing to pain in the left maxilla. She had a fistula in the buccal gingiva between tooth #25 and position #24. There were implants in positions #24 and 23. Tooth #25 already had a crown. The tooth had been affected by secondary caries earlier and had been repaired. A periapical radiograph showed an active inflammatory process in progress from the endodontically treated tooth that greatly worsened the prognosis and could have adversely affected the implants. The prognosis was therefore considered poor and we decided to extract the tooth.

Luxator P4, with its extremely sharp dual-edge blade, was used at the beginning, followed by Luxator P1 once more space had been created. Although the blades of these sophisticated instruments are reinforced with a titanium coating, they should only be used to cut the periodontal ligament and never to elevate the tooth.

When the extraction had been completed, the alveolus was scraped and thoroughly flushed clean with physiological saline solution to prevent infection.

Luxator is a registered trademark owned by Directa AB in Sweden. All Luxator instruments are manufactured in Sweden by Directa. For further information, visit www.directadental.com.