BONN, Germany: Differences in dimensional accuracy between manufacturing methods may influence how well occlusal stabilisation splints fit. Previous laboratory research has generally found milled splints to be more accurate than 3D-printed splints. A recently published in vitro study has added to this evidence by comparing deviations across the internal surfaces of the splints and found that the differences between milling and 3D printing were considerably greater at some sites than at others.
The study assessed 40 maxillary occlusal stabilisation splints manufactured from the same digital design: 20 using 3D printing and 20 using milling. Each splint was scanned after fabrication and its internal surface compared with the design at 42 predefined measurement points.
Overall, the milled splints showed approximately half the dimensional deviation of the 3D-printed splints. The differences between the manufacturing methods were greatest at palatal and occlusal/incisal measurement points, whereas the two methods produced similar results at vestibular points.
Dimensional accuracy and clinical relevance
The researchers also examined whether the splints were narrower or wider across the dental arch than the design by measuring distances between corresponding points on the left and right molars. The 3D-printed splints generally showed contraction relative to the original design, whereas the milled splints tended to be slightly wider at palatal measurement points. The clearest difference between the methods was found at the palatal aspect of the second molars. The authors suggested that polymerisation shrinkage and post-processing may contribute to the dimensional changes observed with 3D printing.
The study pointed out that there is no agreed threshold for clinically acceptable internal fit and that the clinical significance of the measured deviations remains uncertain. A randomised pilot trial found similar patient satisfaction, complication rates and wear with milled and 3D-printed occlusal splints over three months. A smaller clinical study too found no clear differences in retention or wear. Further clinical studies are needed to determine whether manufacturing-related differences affect splint adaptation, patient comfort, tooth mobility, occlusal stability or periodontal outcomes.
The study, titled “Comparison of additive and subtractive digital workflow for the accuracy of removable occlusal stabilization-splints—an in-vitro study”, was published online on 9 October 2026 in Clinical Oral Investigations.
Topics:
Tags:
CHENNAI, India: Digital workflows and sensor-based technologies are being explored in occlusal splint therapy, but it remains unclear whether these ...
3D printing in dental practice is becoming increasingly popular owing to its relatively low barrier to entry and excellent versatility. Improvements in ...
MUNICH, Germany: Additive manufacturing is rapidly gaining importance in removable prosthodontics. To inform clinicians, a recent review has provided an ...
LONDON, England: In the literature on 3D-printed orthodontic appliances, laboratory, ageing and safety findings are often discussed as though they carry the...
Live webinar
Fri. 27 November 2026
8:00 am EST (New York)
Drs. Maarten de Beer, Drs. Erik-Jan Muts
Live webinar
Mon. 30 November 2026
12:00 pm EST (New York)
Live webinar
Mon. 30 November 2026
12:00 pm EST (New York)
Live webinar
Tue. 1 December 2026
1:00 pm EST (New York)
Live webinar
Tue. 1 December 2026
3:00 pm EST (New York)
Dr. Manuel Toledano-Osorio
Live webinar
Tue. 1 December 2026
8:00 pm EST (New York)
To post a reply please login or register